Dsc installation manual power 832


















From our revolutionary control panels, to our industry-leading IP alarm monitoring products and now to our sleek, contemporary self-contained wireless panels, DSC has always been front and center. In order for the Power system to operate properly, the power output capabilities of the main control and expansion devices must not be exceeded.

Use the data presented below to ensure that no part of the system is overloaded and cannot function properly. Includes one keypad. The DSC can use several alarm keypads. All keypads operate in virtually the same way. The burglary zones are individually programmable for many different responses, so zones can be customized to match many applications. Burglar zones can be added using up to 3 zone expander modules, each of which adds 8 zones to the basic system.

This gives the PC a maximum capacity of 32 burglary zones, hardwired or wireless. The fire zone is optimized for 2-wire smoke detectors using the PGM2 terminal.

The connections are compatible with several different 2-wire smoke alarm models, and provide both switched power and alarm functions on the same two terminals. The PGM out provides switched power for resetting the 4-wire smokes, while one of the standard zone inputs is programmed for the fire alarm function. The two PGM outputs can be programmed for many other functions, including relay activation, system status outputs, etc.

Status outputs like system trouble and armed condition are automatically issued by the panel. The user can initiate relay outputs through button presses at a system keypad. In addition, relays can be activated remotely with the addition of an Escort module see below. After many years in the alarm business, I had seen many panels come and go, while others remained popular.

My first requirement was for a system that is keypad programmable. This rules out most of the Radionics line, which require a separate handheld programmer. Secondly, I wanted Alpha display keypads with customizable text. The 4-bedroom, 2-bath house my wife and I live in has four doors and about a dozen movable windows. I wanted each opening on its own zone, which the DSC can support by adding a single 8-zone expansion module.

Filed Pursuant to Rule Registration No. Power Security System pdf manual download of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. DSC Options. Your DSC Power should now have a battery in good shape, a fresh set of your own codes, and working door and window contacts. This alone gives you a good, basic home security system.

The DSC can be customized with zone expanders, enhanced alarm keypads, programming, and other options This site uses cookies to offer you a better browsing experience. By continue to navigate through this site or by clicking Approve, you consent to the use of cookies on your device as described in our. Dameware Nt Utilities 8. The trouble light was on and I lost AC power. The alarm is going off and will not reset now that AC is back. I have unplugged transformed to silence.

How do I reset alarm. Plugging in my master code is not working I bought a new house with a Power